eMonitor: Optical Interface for Energy Meter
eMonitor
pdf
Key Features
  • Led pulse counter of electricity and energy meter settable from 1 to 99 Wh/pulse
  • It manages electricity and energy meter in Wh
  • Digital input for remote alarms
  • Compatible with ENEL energy meter (single phase/three phase); other European energy meters under development
  • Wireless connection to Wippy

The eMonitor connects wirelessly to remote Wippy. It measures the electricity consumed throughout the home also of equipment not linked to the control units.

It is a unique, patented device that attaches optically to the Enel ot other Europeran meter without any type of tampering with it. The optical link allows you to read power and electricity consumed as counted by the counter, the device transmits it wirelessly to the remote Wippy that displays it in real time.

Option of remote control charts measures up to two years ago displayed on Wippy.

 
 
Technical Specifications
General Characteristics
Chip Ember EM250
Compatible IEEE 802.15.4
Stack EmberZnet 3.5.x (ZigBee PRO)
Modbus/RTU
Device address settable via internal dip-switch
Wall mounting with screws
Cable gland: PG9
RF Characteristics
Frequency: 2405 MHz ÷ 2480 MHz
Modulation: DSSS
Nominal transmission power: 10mW (10 dBm)
Reception sensitivity: -97 dBm
External antenna gain: 5,5 dB
Coverage outdoor/indoor: 200m/50m
Supply
12-24 Vdc/Vac; 100mA; 50/60Hz
feeder incl. 230 Vac (±20%); 50/60Hz
Digital Inputs
Electronic type not insulated inputs for clean contact.
Short circuit current 0,01mA. Use self-cleaning contact
Connections
Terminal blocks (3,81 mm pitch)
Environment Parameters
Operating temperature: -10 ÷ +60°C; <80% U.R. not condensing
Storage temperature: -20 ÷ +70°C; <80% U.R. not condensing
Protection degree: IP 55
Compliant with 2006/95/EEC, 89/336/EEC, 99/5/EEC directives
Reference Norms:
ETSI EN 300 328: Radio Compatibility for digitals wide band transmissions
ETSI EN 301 489: Radio Compatibility
EN 61000-6-2: Electromagnetic Compatibility - Emissions
EN 61000-6-3: Electromagnetic Compatibility - Immunity
EN 60950-1: Electric Safety