Key Features
- Real Time Electricity Active Power Measurement up to 15 kW with external CT included
- Electricity Energy Counter
- Digital output to drive external high power relay
- Stand-by killer
- Override push-button
- CT included with core split
- Din Rail Mounted
The eMeter connects wirelessly to remote Wippy. It measures the electricity consumed throughout the home also of equipment not linked to the control units. It is positioned to the nearest electrical panel where the Enel (or other European) meter is far (outside the apartment, the store, etc..) and therefore it is not possible to use the eMonitor. It reads power and electricity consumed as counted by the counter, the device transmits it wirelessly to the remote Wippy that displays it in real time. Option of remote control charts measures up to two years ago displayed on Wippy.
| General Characteristics |
Chip Ember EM250
Compatible IEEE 802.15.4
Stack EmberZnet 3.5.x (ZigBee PRO)
Modbus/RTU
Device address settable via radio commands
|
| RF Characteristics |
Frequency: 2405 MHz ÷ 2480 MHz
Modulation: DSSS
Nominal transmission power: 2mW (3 dBm)
Receiver sensitivity: -95 dBm
Internal antenna gain: 0 dB
Range outdoor/indoor: 100m/30m
|
| Supply |
90/250 Vac; 1W; 50/60Hz
|
| Measurement |
Active Power [W]
Energy consumption [Wh]
Energy consumption measurement time [second]
Working conditions: 230V-70A max.
|
| Digital Outputs |
For auxiliary relay 230 Vac, 40mA max |
| Connections |
Terminal blocks (5,08 mm pitch)
|
| CT |
70A max.
|
| Environment Parameters |
Operating temperature: -10 ÷ +60°C; <80% U.R. not condensing
Storage temperature: -20 ÷ +70°C; <80% U.R. not condensing
|
Compliant with 2006/95/EEC, 89/336/EEC, 99/5/EEC directives
Reference Norms:
|
ETSI EN 300 328: Radio Compatibility for digitals wide band transmissions
ETSI EN 301 489: Radio Compatibility
EN 55014-1:2006 + A 1:2009: Electromagnetic Compatibility - Immunity
EN 61000-3-2:2006: Electromagnetic Compatibility - Emissions
EN 61000-3-3:2008: Electromagnetic Compatibility - Emissions
EN 55014-2: Electromagnetic Compatibility - Immunity |